Federal opportunity · Sources Sought
ClosedBrand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
A070764SS · Dept of Defense · SAM.gov
Closed. Responses were due Oct 26, 2026, 1:00 PM ET.
- Responses due
- Oct 26, 2026, 1:00 PM ET
- Posted
- Oct 14, 2026
- NAICS code
- 238220 · Plumbing, Heating, and Air-Conditioning Contractors
- Set-aside
- None
- Place of performance
- JBSA Ft Sam Houston, TX
- Notice type
- Sources Sought
- Solicitation number
- A070764SS
- Official notice
- View on SAM.gov →
Similar open opportunities
- MXRD 26-0101 Clean HVAC VentsDept of Defense · Due Nov 6, 2026 · Under a day left
- 16292 Steam Boiler ReplacementDept of Defense · Due Nov 11, 2026 · 5 days left
- Replacement of 10 Ton HVAC Unit, Bldg.11, PR ANGDept of Defense · Due Nov 12, 2026 · 5 days left
- Repair Mechanical Systems IDIQ (FY 27-32)Dept of Defense · Due Nov 12, 2026 · 6 days left
- L7WC02_ B670 Paint Booth and HVACDept of Defense · Due Nov 12, 2026 · 6 days left
- FY27 HVAC Maintenance ServiceDept of Defense · Due Nov 13, 2026 · 7 days left
What the agency was buying
The 502d Contracting Squadron (502CONS), on behalf of the 502d Civil Engineer Squadron (502CES), is conducting market research to determine: The availability and technical capability of industry sources (small and large businesses) to furnish and install 48 each 1.25-ton Dedicated Outside Air System (DOAS) Water-Source Heat Pumps (WSHP) which meet strict salient dimensions and environmental characteristics. The appropriate competitive acquisition strategy, including small business socio-economic set-aside determinations (RFO Part 19 Small Business - Rule of Two). Standard commercial practices, lead times, supply chain constraints, warranty terms, and pricing structures IAW RFO 10.002(b) Market Research. The contractor shall provide all personnel, management, equipment, tools, rigging, materials, and supervision necessary to execute the turnkey removal and replacement of 48 ceiling-suspended DOAS WSHP installed above exterior breezeway ceilings in B3631 and B3635 at JBSA Ft Sam Houston (FSH) San Antonio Military Medical Center (SAMMC) Dormitory Annex.
Show the full description · 143 more wordsShow less
This new requirement is projected to be a Firm-Fixed Priced (FFP) Purchase Order as a Commodity (Procurement) with incidental Services (Removal and Installation) buy. Key Salient Characteristics: Capacity: 1.25 Tons (15,000 BTUH nominal), airflow of 160 L/s (~340 CFM) at 50 Pa ESP. Configuration: Horizontal, ceiling-plenum suspended, right-hand return air arrangement.
Access Dimension Constraint: Existing units are installed above metal panel breezeway ceilings accessible through structural door openings measuring approximately and replacement units must physically fit through these envelope openings without requiring structural building demolition. Refrigerant: Low-GWP refrigerant (e.g., R-454B or R-32). R-410A is strictly prohibited. Hydronic Pre-Heat Coil & Reheat: Integral 3.75 kW water-source pre-heat coil (3-way, 2-position control valve) and factory hot gas reheat (HGRH) / hot gas bypass (HGBP) for 100% outside air continuous dehumidification.
Controls Integration: Complete integration into the installation's central Building Automation System (BAS via BACnet IP/MSTP).
From the official notice on SAM.gov.